Skip to content
Your delivery country uses a different language.
Monters
YT-6753 Wyciskacz do mas silikonu pistolet mocny YATO 6753 YT-6753 Wyciskacz do mas silikonu pistolet mocny YATO 6753 YT-6753 Wyciskacz do mas silikonu pistolet mocny YATO 6753 YT-6753 Wyciskacz do mas silikonu pistolet mocny YATO 6753 Yato

YT-6753 Reinforced Caulking Gun for 300 ml Silicone and Adhesive Cartridges

Code: YT-6753
In stock Lead time: 24 h
60,64 zł
/ pcs
49,30 zł net · VAT 23%
Shipping 24 h
VAT invoice
Secure payments
Manufacturer banner TOYA S.A. (Yato)
Genuine TOYA S.A. (Yato) product

Yato YT-6753 caulking gun for thick cartridge compounds

The manual cradle gun is designed for typical rigid 300 ml cartridges. The painted steel cradle supports the cartridge, and the shaped handle is aluminium. The reinforced frame and double plunger guide keep pressure aligned with the cartridge. This is useful for thicker silicones, adhesives, sealants and other compounds in compatible cartridges.

Checking cartridge fit

The manufacturer specifies 300 ml capacity, 225 mm cartridge length and 49 mm diameter. Compare them with your cartridge and check how its flange sits. A similar volume does not determine the cartridge shape. Soft foil packs need a gun designed for that format. When choosing the compound, check the substrate, joint width and temperature limits from its manufacturer.

Preparing and applying the bead

Clean the substrate as directed by the compound manufacturer and prepare all sections to be filled. Retract the plunger and seat the rigid cartridge straight in the cradle. Prepare its outlet as instructed on its label and attach the nozzle. Cut the tip to the planned bead width. Test flow and bead size on a sample before applying to the work.

Move the nozzle steadily and match hand pressure to the compound's consistency. Very thick products may flow more slowly at lower temperatures. Follow the compound's temperature range. If resistance rises suddenly, check the nozzle for blockage and the alignment of cartridge and plunger before pressing again. Release plunger pressure at the end to limit further flow.

Workshop use and tool care

The gun suits finishing and renovation jobs, including sealing a joint or running mounting adhesive down a workpiece. Check for dents in the cartridge and confirm that the plunger meets its base centrally. Clean the cradle and plunger using a method suited to the compound before it sets. On the next cartridge change, check the plunger moves smoothly so you can control the application.

After cleaning, store the gun with the plunger unloaded. Close an open cartridge according to its manufacturer's instructions. Use protection suited to the compound. Ventilation and spill clean-up depend on the product inside the cartridge. After a longer break, inspect the nozzle for cured compound.

When one cartridge is used on several sections, prepare a place to set the gun down between runs. Test again after changing the nozzle, since its opening affects the amount applied. Before fitting the next cartridge, retract the plunger and clean the rim seat.

Technical data

ModelYT-6753
Manufacturer GTIN5906083967535
Constructionreinforced cradle, double plunger guide
Manufacturer cartridge capacity300 ml
Manufacturer cartridge length225 mm
Manufacturer cartridge diameter49 mm
Cradle materialpainted sheet steel
Handle materialaluminium
Manufacturer
Yato
Product code (SKU)
YT-6753
Unit
pcs
Weight
1 kg
VAT rate
23%
Category
Applicators, Guns & Sealant Tools
Manufacturer
TOYA S.A. (Yato)
ul. Sołtysowicka 13-15, 51-168 Wrocław, Polska
+48 71 32 46 200
Responsible person in the EU
TOYA S.A.
ul. Sołtysowicka 13-15, 51-168 Wrocław, Polska
Warnings

Hand tools and power tools must be used in accordance with the manufacturer's operating instructions. Suitable personal protective equipment (goggles, protective gloves, workwear) must be used during work. Knowledge of the safety instructions and of correct installation procedures is required. Keep power tools away from children and unauthorised persons.

Usage instructions

The product must be used only for its intended purpose and in accordance with the manufacturer's instructions supplied with the product or available on the manufacturer's website. Installation and fitting of windows and doors should be carried out by persons with appropriate professional qualifications. Store tools in a dry place, protect them from damage and regularly check their technical condition before use.

Returns within 14 days
14-Day Returns

You have the right to withdraw from the contract within 14 days of receiving the product, without giving a reason. Returned items must show no signs of use beyond normal inspection. Returns can be registered online. Return shipping costs are covered by the buyer, and the refund is issued within 14 days of receiving the returned parcel.

Customer reviews

This product has no reviews yet. Be the first!

Related products

Whole category

We use cookies to keep the store working and improve your experience. More.