Metal expansion frame anchors BENOX KO 10×112 mm, 100 pcs. for windows and doors
Frame anchor BENOX KO 10 × 112 mm – 100 pcs.
BENOX KO 10 × 112 mm is a metal expansion fixing used to install window and door frames. It connects the profile to the substrate by means of a steel sleeve that expands as the screw is tightened. It allows through fixing and stable seating of the window or door unit.
Steel construction and corrosion protection
The anchor sleeve is made from zinc-plated steel. The metric screw has an electroplated zinc coating, while the expansion cone is made from ZnAl alloy. The design provides mechanical anchorage once the fixing is inserted into a correctly drilled hole.
Fixing parameters
The fixing has a diameter of 10 mm and a length of 112 mm. The minimum anchorage depth is 40 mm. Select the size to suit the frame thickness, installation gap width and substrate type.
Applications
- PVC, timber and metal window frames,
- entrance and internal door frames,
- timber components secured to walls,
- concrete, stone, solid brick and calcium silicate masonry,
- selected masonry substrates and aerated concrete.
Step-by-step installation
- Position the frame and stabilise it.
- Mark the fixing positions.
- Prepare holes with a diameter of 10 mm.
- Clean the holes and insert the anchors through the frame into the substrate.
- Tighten the screws to expand the sleeves.
- Check the frame geometry and anchorage stability.
Technical data
| Brand | BENOX |
| Model | KO 10 × 112 |
| Type | expansion frame fixing |
| Diameter | 10 mm |
| Length | 112 mm |
| Minimum anchorage depth | 40 mm |
| Sleeve | zinc-plated steel |
| Screw | electroplated zinc-coated steel |
| Cone | ZnAl alloy |
| Installation | through fixing |
| Pack size | 100 pcs. |
- Manufacturer
- BENOX
- Product code (SKU)
- KO10X112
- EAN code
- 5905458503040
- Unit
- pcs
- Weight
- 2 kg
- VAT rate
- 23%
- Category
- Dowels, screws, self-tapping screws, chemical anchors
BENOX products, including expansion plugs, hammer-in fixings, frame fixings, screws, bolts, nuts, frame connectors and other fastening components, must only be used for their intended purpose and in accordance with their technical parameters. Metal components may have sharp points, edges and threads, so suitable protective gloves and eye protection should be worn during installation. Drilling may generate dust and flying particles and may cause the tool to jam; appropriate personal protective equipment and suitable accessories must be used. Plugs, screws and connectors must be selected according to the type and condition of the substrate, the thickness of the component being fixed and the expected load. Do not use cracked, deformed, corroded components or components with damaged threads. For chemical anchors, also follow the label and safety data sheet, provide adequate ventilation and avoid contact with skin and eyes. The fixing must not be loaded before the required curing time has elapsed. Keep small fastening components and chemical products out of reach of children. Detailed warnings and requirements for the specific product take precedence over these general safety rules.
Before installation, check that the selected plug, screw, bolt, connector or anchor is suitable for the intended substrate and application. Consider the type and condition of the base material, required load capacity, thickness of the component being fixed and environmental conditions. The installation hole must have the diameter and depth specified for the particular product; drill it using a suitable drill bit and, where required by the fixing system, thoroughly remove drilling dust and debris. Expansion and frame fixings must be installed to the required anchoring depth and screws tightened with a suitable tool without excessive torque. Hammer-in fixings must be installed using the intended setting method without damaging the plug body or the component being fixed. For chemical anchors, use the appropriate mixing nozzle and observe the specified application temperature, working time and curing time; do not load the fixing before the resin has fully cured. For load-bearing fixings, always follow the technical parameters and documentation applicable to the specific product. Store products in a dry place protected from moisture, corrosion, contamination and mechanical damage; store chemical products in accordance with the label and safety data sheet.
You have the right to withdraw from the contract within 14 days of receiving the product, without giving a reason. Returned items must show no signs of use beyond normal inspection. Returns can be registered online. Return shipping costs are covered by the buyer, and the refund is issued within 14 days of receiving the returned parcel.
Customer reviews
This product has no reviews yet. Be the first!
Related products
Whole category
SALE
Klimas SM 8×80 mm Hammer-In Fixing countersunk collar 100 pcs
KLIMAS WKRĘT-MET Sp. z o.o.
Klimas SM 8×60 mm Hammer-In Fixing countersunk collar 100 pcs
KLIMAS WKRĘT-MET Sp. z o.o.
monters'">